In fires, most of the matters at home or in the office turn into a handful of ashes because of the high heat to 800~1000°C Diplomat Fire Safes are designed to block heat and smokes from outside so that they can protect the inside matters.

  1. Diplomat Safes passed in fire test by world class fire testing institues.
  2. - Diplomat Safe won KS mark first in Korea 1984
  3. - Diplomat Double door safe is the only one passed in RISE fire test among Korean safes
  4. - Diplomat Data safe passed in RISE fire test first in Asia.
Fire Test Process
  • 1. Test Safe Specimen Loaded

  • 2. Heating Test

  • 3. Heating Test

  • 4. Check Result

  1. 1. Test Safe Specimen Loaded
  2. A specimen safe for fire test is loaded in the furnace. Temperatures are checked with 6 thermo-sensers at six points (up, down, front, back and sides).
  3. 2~3. Heating Test
  4. The safe is heated up to 1,010℃ in the airtight furnace over 60 minutes to 120 minutes, depending models. (The maximum inside temperature allowed to pass is 150℃.
  5. 4. Check Result
  6. After heat, the test safe is taken out to check if the inside matters are safely protect.
  • Furnace Temperature

  • Internal Temperaturel of Tested Safe

  • Data safe Temperature

Data safe must keep less than 50℃ inside during the fire test, and the inside matters must not be deformed but be operated normally in the computer. Diplomat Data safe passed in RISE fire test.

Fire Class
  • P-1
    TKS
  • 60, 90, 120
    Paper
  • 60, 90, 120
    Data
  • 60, 90
    Diskette
  1. P Paper
  2. 1TKS 1 hour KS rapid heating, shock
  3. Data Grade for the media to be stored at less than 50℃ in fire.
    (Available Media - 3.5", CD)
  4. Diskette Grade for the media to be stored at less than 30℃ in fire.
    (Available Media - 3.5", CD, 4㎜ DAT, 8㎜ A/T, DLT, LT, 3590 Cartridge)
World Class Fire Resistance Test Certification
Passed the world-class certification authority test

Diplomat Safes passed in fire test by world class fire testing institutes, Sweden(RISE) and United States(UL) etc.

  • UL (Class 350-1hr)Fire Resistance tested and certified

  • GOSTFire Resistance tested and approved by the Russian Committee of Certification

  • P (60P/90P/120P)RI.SE, Research Institutes of Sweden Fire Test approved

  • KS(KSG 4500P-1TKS)Fire Resistance & Impact tested under KSG4500

Fireproof Safes
Fire site - June, 2012 in Yongin City, Gyeonggi-do
Fire site - December, 2012 in Yangju City, Gyeonggi-do